Notes
To produce fine joint, the left side and bottom of the screen are secure with adhesive double coated tape. Make sure the
replaced screen is attached closely to the left and bottom sides of the panel. If not attached closely, the screen will discon-
nect from the panels when it expands and contracts according to temperature and humidity changes, or in the worst case,
drop off.
In replacements, make sure not to leave dust and dirt between the lenticular sheet and fresnel lens.
Take note of the front and back of the screen. Unnatural images will be produced when these sides are mistaken.
As dust and oil adhere easily to the screen, when replacing, always put on gloves (also protects against hazards).
As the lenticular sheet is very thin and tears easily, handle it with extreme care.
The fresnel lens is such that convex lenses are arranged in flat. Do not expose it to direct sunlight to prevent fire hazards,
burns, and loss of eyesight.
When performing replacements at high places, work very carefully as small mistakes may lead to serious accidents.